- Tone and traced the Striker for D134A Vehicle Bay Corridor, routed from existing cabinet to AC12, connected and wired it to AC12.
- Tested device and Striker is dead. Replaced it with a new one, observed issue with door latch not making proper contact with the new striker, requires extensive grinding of the striker frame.
- Swapped the new striker for D131B's retained striker, tested the device and is OK.
- Started cable management for the network cables on the server rack and some of the access control cables.
|
|
Work Completed |
Technician |
Check-in |
Check-out |
Actual Hrs |
|
|
1 |
- Troubleshooted issue with D131B CSI Decon Vehicle Bay 2nd Reader. Observed power stuttering when enabling In/Out option in Verkada Command in order to enable 2nd Reader, 1st Reader is OK and functions as it should be.
- Tried swapping the 2nd Reader with another reader, symptoms still shows the same. Concluded that it might be an issue with either the port for the 2nd Reader itself or with AC12 as a whole. Reported findings to Kevin, he advised that will need to get in with Verkada Support to escalate issue. |
Sean Bacani
|
04/07/2026 09:30 am |
04/07/2026 12:00 pm |
02:30
|
|
|
2 |
- Tone and traced the Striker for D134A Vehicle Bay Corridor, routed from existing cabinet to AC12, connected and wired it to AC12.
- Tested device and Striker is dead. Replaced it with a new one, observed issue with door latch not making proper contact with the new striker, requires extensive grinding of the striker frame.
- Swapped the new striker for D131B's retained striker, tested the device and is OK.
- Started cable management for the network cables on the server rack and some of the access control cables. |
Sean Bacani
|
04/07/2026 01:00 pm |
04/07/2026 04:30 pm |
03:30
|