Network down but all network equipment shows no signs of issues. Proceed to reboot SonicWALL, GTA Modem, Network switch and Server. Perform ping tests after equipment reboot and noted ping test is stable for 1 minute then drops. Remove all network lines from network switch and left only server and SonicWALL connected. Ping stable. Begin to reconnect all network devices 1 by 1 and monitor. Network is now up and stable. Suspect issue is Mitch's workstation onboard network card. TTA to purchase a USB to Ethernet adapter and use on Mitch's workstation to test further. If issue is also present on the USB to Ethernet adapter, Mitch's workstation will need to be replaced.
|
|
Work Completed |
Technician |
Check-in |
Check-out |
Actual Hrs |
|
|
1 |
Network down but all network equipment shows no signs of issues. Proceed to reboot SonicWALL, GTA Modem, Network switch and Server. Perform ping tests after equipment reboot and noted ping test is stable for 1 minute then drops. Remove all network lines from network switch and left only server and SonicWALL connected. Ping stable. Begin to reconnect all network devices 1 by 1 and monitor. Network is now up and stable. Suspect issue is Mitch's workstation onboard network card. TTA to purchase a USB to Ethernet adapter and use on Mitch's workstation to test further. If issue is also present on the USB to Ethernet adapter, Mitch's workstation will need to be replaced. |
Kevin Hsueh
|
04/07/2022 09:07 am |
04/07/2022 10:48 am |
01:41
|